Illustration : Upper segment of control frame is depicting total flatness specification ( 1mm) for overall complete area of part. Lower segment of control frame depicting flatness specification (0.3 mm) for any small part on the surface 35mmX 35mm on overall area. Modifier F represents free condition of part while inspection. i.e. Part to be kept on surface plate without any clamping load on it.
Inspection Procedure :
- Nandkumar Walve, Corporate Trainer on Quality
(nnwalve@gmail.com, 9820424387, https://ungliiart.com/TrainingDetails.php)